Features
Specifications
Current: 1250A
Voltage Rating: 12kV
Keywords: High Voltage Electrical Isolator
Material: Ceramic+Steel
Usage: Protection
Quality: 3units
Highlight:

High Voltage Hookstick Operated Switch

,

GW9-10 Hookstick Operated Switch

,

hookstick switch Easy Installation

Basic Infomation
Place of Origin: China
Brand Name: HengAnshun
Model Number: GW9-10/1250A
Payment & Shipping Terms
Packaging Details: Export wooden case packing
Delivery Time: 10 work days
Supply Ability: 10000 units/month
Product Description

GW9-10 High Voltage Hookstick Operated Switch Easy Installation New Type Single Phase Electrical Isolator

 

 

Product Description:


 

GW9-10 Series high voltage electrical isolator is an electrical switch that is designed to isolate a section of an electrical network or system from the rest of the system for maintenance or repair purposes. It is typically used in high voltage power transmission and distribution systems.

The switch is designed to open and close under normal or abnormal conditions, such as a fault or overcurrent. When the switch is open, it physically disconnects the section of the system from the rest of the network, preventing the flow of electricity to that section.

High voltage electrical isolators are typically designed to operate at voltages between 600 volts and 765,000 volts, and they can be operated manually or automatically. They are typically installed in substations or on power poles, and they are an important component of the electrical grid infrastructure.

 

 

 

Feature:


 

1.High Voltage Rating: High voltage isolator switches are designed to withstand high levels of voltage, typically ranging from several thousand volts to several hundred thousand volts.

2.Robust Construction: High voltage isolator switches are typically made of materials that are highly resistant to electrical arcing, corrosion, and other forms of damage, such as porcelain or polymer.

3.Arc Chutes: Many high voltage isolator switches are designed with arc chutes, which help to dissipate the heat generated by electrical arcing and prevent damage to the switch.

4.Earth Switch: Some high voltage isolator switches are equipped with an earth switch, which provides an additional level of safety by grounding the isolated section of the circuit.

5.Interlocking Mechanism: To prevent accidental closure of the switch while maintenance work is being carried out, many high voltage isolator switches are equipped with an interlocking mechanism that prevents the switch from being closed until all safety procedures have been followed.

6. Visual Indicators: High voltage isolator switches may also include visual indicators, such as lights or flags, that provide a clear indication of whether the switch is in the open or closed position.

.

 

 

 

Structure:


 

1.Porcelain Insulator Body: The insulator body is the main component of the isolator, and is typically made of high-strength porcelain. It is designed to provide electrical insulation between the conductor and supporting structure, and is molded into the desired shape and size.

2.Metal End Fittings: The metal end fittings are attached to the insulator body and provide a means of connecting the isolator to the conductor and supporting structure. They are typically made of galvanized steel or other corrosion-resistant material, and may be designed with special features such as clevises or ball-and-socket joints for easy installation.

3.Sealing Compound: A sealing compound is used to seal the joint between the insulator body and metal end fittings, preventing moisture and contaminants from entering the interior of the isolator.

4.Hardware: Hardware such as bolts, nuts, and washers are used to secure the metal end fittings to the insulator body and supporting structure.

Fitting Caps: Fitting caps are used to protect the metal end fittings from corrosion and damage, and may be made of plastic or other materials.

5.Additional Features: Depending on the specific application, porcelain high voltage electrical isolators may be designed with additional features such as insulating barriers, arc chutes, and earth switches to improve their performance and safety.

matters causing fire

 

 

Operation:


 

1 Preparation: Before operating the switch, the circuit should be de-energized and properly grounded to prevent any electrical hazards. The switch should be inspected for any signs of damage or wear and tear.
2 Closing the switch: To close the switch, the operator manually or remotely moves the switch handle or control lever to the closed position. This connects the circuit to the power source, allowing current to flow through the circuit.
3 Opening the switch: To open the switch, the operator manually or remotely moves the switch handle or control lever to the open position. This disconnects the circuit from the power source, interrupting the flow of current.
4 Arc management: When the switch is opened, an electrical arc may occur between the contacts, which can be dangerous and cause damage to the switch. To manage the arc, the switch may be equipped with devices such as arc chutes or blowout coils.
5 Safety: Operators of high voltage disconnect switches must follow proper safety procedures to prevent electrical hazards. This may include wearing personal protective equipment, working in teams, and following lockout/tagout procedures.

 

 

 

Technical Parameters:


 

Serial No. Parameter Unit Data
1 Rated Voltage kV 12
2 Rated Current Model No. (H)GW9-12(W)/630-20 A 630
(H)GW9-12(W)/1000-20 1000
(H)GW9-12(W)/1250-31.5 1250
3 4s Short-time withstanding current Model No. (H)GW9-12(W)/630-20 kA 50
(H)GW9-12(W)/1000-20 50
(H)GW9-12(W)/1250-31.5 80
4 Rated Insulation Level Lightning surge withstand voltage(peak) Polar-to-Earth
(Positive & Negative)
kV 75
Interfracture
(Positive & Negative)
85
Industrial frequency withstand voltage
(1 min)
(Effective value)
Dry Test/Wet Test Polar-to-Earth 42(Dry)
34(Wet)
Interfracture 48(Dry)
48(Dry)
48(Dry)
40(Wet)
5 Main Circuit Resistance μ Ω 630
1000
1250
6 Mechanical Life Time times 50
50
80

 

GW9-10 High Voltage Hookstick Operated Switch Easy Installation New Type Single Phase Electrical Isolator 0

GW9-10 High Voltage Hookstick Operated Switch Easy Installation New Type Single Phase Electrical Isolator 1GW9-10 High Voltage Hookstick Operated Switch Easy Installation New Type Single Phase Electrical Isolator 2

 

 

GW9-10 High Voltage Hookstick Operated Switch Easy Installation New Type Single Phase Electrical Isolator 3

GW9-10 High Voltage Hookstick Operated Switch Easy Installation New Type Single Phase Electrical Isolator 4

GW9-10 High Voltage Hookstick Operated Switch Easy Installation New Type Single Phase Electrical Isolator 5

GW9-10 High Voltage Hookstick Operated Switch Easy Installation New Type Single Phase Electrical Isolator 6

Recommended Products
Get in touch with us
Contact Person : Sherlin
Characters Remaining(20/3000)